Diesel Incineration

Bus or Coach

The WC16 (16kW) diesel incinerator for mobile and military applications with optional heating and handwash benefits

The WC16 has been developed for use where disposal of human waste is a major environmental and logistical problem. The WC16 eliminates the normal cost and problems of disposal. It operates with conventional or low water usage toilets which include an integral macerator pump, as a result costly water storage is greatly reduced.

The WC16 has the capability of incinerating up to 18 litres of waste per hour, making it extremely versatile for welfare applications everywhere.

Space heating and hot water is obtained via a Hydronic 5 with fan matrix and chlorifier / boiler.
Telemetry is available for remote monitoring and security alarms.

The WC16 meets all required Environmental and Health and Safety regulations - details of which are available on request.

How the System Works

After flushing, all toilet waste is passed through the macerator pump, which is then conveyed to the waste holding tank. A level sensor within the tank alerts the incinerator that there is waste requiring incineration and the incineration process begins.

A measured quantity of waste is pumped into the chamber and combustion commences, whereupon all contents of the chamber are incinerated leaving a sterile chamber. When the incineration process is complete combustion ceases and the incinerator begins its cool down cycle.

If the holding tank level sensor indicates there is still waste in the holding tank, further incinerations are initiated until the tank is empty.

Waste Incineration

Useful Information